1.所需filesets(AIX安装盘上有,从IBM网站下载其ptf):
devices.common.IBM.fc.rte(升级到4.3.3.75),
devices.fcp.tape.rte(升级到4.3.3.77)。
devices.common.IBM.fc.rte(升级到4.3.3.75),
devices.fcp.tape.rte(升级到4.3.3.77)。
2.所需驱动程序:dulldrv选装其中的devices.pci.df1001f8,而不装其余两个FILESETS,另外还要装上相应的PTF。
3.安装好这些程序后,此时已经可以在设备列表中看到有FC Adapter,但不能在添加TAPE时看到lp8000,只能看到几个SCSI卡,还要重启系统后才能进行正常的添加驱动器。
4.通过配置snc确定几个驱动器对应的TARGET,这样可以在添加驱动器时避免依次对16个CONNECTION ADDRESS进行试探。
# lsdev -C|grep fc
fchan0 Available 20-58 PCI Fibre Channel Adapter
fcp0 Available 20-58-00 Fibre Channel FCP Interface
# lsdev -C|grep fc
fchan0 Available 20-58 PCI Fibre Channel Adapter
fcp0 Available 20-58-00 Fibre Channel FCP Interface
# lsdev -C|grep rmt
rmt0 Available 20-58-00-0,2 Other SCSI Tape Drive
rmt1 Available 20-58-00-0,4 Other SCSI Tape Drive
rmt2 Available 20-58-00-0,6 Other SCSI Tape Drive
rmt3 Available 20-58-00-0,8 Other SCSI Tape Drive
rmt0 Available 20-58-00-0,2 Other SCSI Tape Drive
rmt1 Available 20-58-00-0,4 Other SCSI Tape Drive
rmt2 Available 20-58-00-0,6 Other SCSI Tape Drive
rmt3 Available 20-58-00-0,8 Other SCSI Tape Drive
# pwd
/etc/LGTOuscsi
# ./inquire
scsidev@0.1.0:IBM CDRM00203 |CD-ROM, /dev/rcd0
scsidev@0.6.0:IBM DDYS-T18350N |Disk, /dev/rhdisk0
scsidev@0.10.0:IBM DDYS-T18350N |Disk, /dev/rhdisk1
scsidev@3.0.0:PATHLGHTSAN Gateway 329c|(Unknown Device Type c)
scsidev@3.0.1:ADIC Scalar 1000 2.30|Autochanger (Jukebox)
scsidev@3.0.2:SONY SDX-500C |Tape, /dev/rmt0.1
scsidev@3.0.3:SONY SDX-500C |Tape, /dev/rmt1.1
scsidev@3.0.4:SONY SDX-500C |Tape, /dev/rmt2.1
scsidev@3.0.5:SONY SDX-500C |Tape, /dev/rmt3.1
/etc/LGTOuscsi
# ./inquire
scsidev@0.1.0:IBM CDRM00203 |CD-ROM, /dev/rcd0
scsidev@0.6.0:IBM DDYS-T18350N |Disk, /dev/rhdisk0
scsidev@0.10.0:IBM DDYS-T18350N |Disk, /dev/rhdisk1
scsidev@3.0.0:PATHLGHTSAN Gateway 329c|(Unknown Device Type c)
scsidev@3.0.1:ADIC Scalar 1000 2.30|Autochanger (Jukebox)
scsidev@3.0.2:SONY SDX-500C |Tape, /dev/rmt0.1
scsidev@3.0.3:SONY SDX-500C |Tape, /dev/rmt1.1
scsidev@3.0.4:SONY SDX-500C |Tape, /dev/rmt2.1
scsidev@3.0.5:SONY SDX-500C |Tape, /dev/rmt3.1
遇到的问题:
但在选用20-58-00-8,0时遇到问题,用LEGATO自带的INQUIRE程序不能查到rmt3,估计是8数值太高,换用一个较小的数值就没有问题。
但在选用20-58-00-8,0时遇到问题,用LEGATO自带的INQUIRE程序不能查到rmt3,估计是8数值太高,换用一个较小的数值就没有问题。
在作nsrjb检测机械手时应注意要选用autodected scsi,这样才可以检测到机械手.